Lancetech Limited

Lab guides and glossary

Plain answers to the questions a working laboratory asks: choosing and looking after HPLC and GC columns, filtering and extracting samples, picking vials, caps and septa, and the conversion tables you reach for every week.

HPLC columns and methods

What is chromatography? Definition and main types

Chromatography explained: how a mobile and a stationary phase separate a mixture, the main types (HPLC, GC, TLC, column, SPE) and what a chromatogram shows.

What is column chromatography? Packing, solvents and practice

Column chromatography in practice: silica gel and alumina grades, how much sorbent to use, wet and dry packing, picking the solvent by TLC, and flash columns.

HPLC defined and explained

HPLC explained: what high performance liquid chromatography is, the parts of the system, separation modes, isocratic and gradient runs, and HPLC versus UHPLC.

HPLC terms and equations explained

HPLC terms and equations in one place: retention factor, selectivity, plate number, HETP, resolution, tailing factor, van Deemter, back pressure, void volume.

How to select a suitable HPLC column

How to choose an HPLC column: separation mode, bonded phase (C18, C8, phenyl, cyano, amino, PFP), particle and pore size, length and inner diameter, pH range.

HPLC column selection by USP L number and Ph. Eur. description

What the USP L numbers mean (L1 C18, L7 C8, L3 silica, L10 cyano, L11 phenyl and more), how Ph. Eur. describes stationary phases, and how to choose a column.

HPLC analysis under USP <621> and Ph. Eur. 2.2.46: permitted adjustments

What you may change in a pharmacopoeial HPLC method without revalidation: column length and particle size (L/dp), flow, temperature, pH and mobile phase.

Solvents for HPLC: grades, UV cut-off and handling

HPLC solvents explained: HPLC, gradient and LC-MS grade, UV cut-off of acetonitrile, methanol and others, viscosity and pressure, water quality and storage.

Mobile phases in HPLC: preparation, buffers, filtration and degassing

How to prepare an HPLC mobile phase: measuring and mixing, choosing a buffer by pKa, adjusting pH, volatile buffers for LC-MS, filtration and degassing.

Choosing the right eluent in HPLC

How to choose an HPLC eluent: solvent strength of methanol, acetonitrile and THF, the effect of pH on acids and bases, isocratic or gradient, and HILIC.

Fast chromatography: raising the productivity of HPLC methods

How to make HPLC faster without losing separation: L/dp, sub-2 µm and solid-core particles, flow and gradient scaling, pressure, and extra-column volume.

Effect of temperature on retention times in chromatography

Why HPLC retention time changes with temperature: the 1 to 2% per °C rule, viscosity and pressure, selectivity shifts, solvent pre-heating and column oven use.

Verification of peak purity in HPLC

How to check peak purity in HPLC: diode array spectral comparison, wavelength ratios, a second column or pH, mass spectrometry, and why a pass is not proof.

The importance of HPLC standards

Why HPLC results depend on the standard: primary, secondary and certified reference materials, external and internal standard calibration, storage and handling.

HPLC system care

Installing an HPLC column and getting started

How to install a new HPLC column: check the shipping solvent, flush the system, connect in the flow direction, make fittings correctly, equilibrate and test.

Tips for the equilibration of HPLC columns

How long to equilibrate an HPLC column: column volumes for isocratic, gradient, ion-pair and HILIC methods, a column volume table, and how to tell it is ready.

How to maintain and store HPLC columns correctly

Make an HPLC column last: stay inside pH, pressure and temperature limits, filter samples, use a guard column, flush out buffer and store in the right solvent.

Tips for the regeneration and cleaning of HPLC columns

How to clean and regenerate an HPLC column: check the column is the cause, wash sequences for reversed and normal phase, back-flushing, what cannot be fixed.

Testing the quality of an HPLC column

How to test an HPLC column's performance: reproduce the certificate test, measure plate number, peak symmetry, retention factor and pressure, and track them.

Use of HPLC inline filters in chromatography

Inline filters for HPLC and UHPLC: where they sit, 0.5 µm or 2 µm frits, how they differ from guard columns and solvent inlet filters, and when to replace them.

Preventing air bubbles in the HPLC system

Why air bubbles form in an HPLC system, how to recognise them (pressure ripple, baseline spikes, drifting retention) and how to remove and prevent them.

Preventing dead volume in chromatography

What dead volume and extra-column volume are, how they broaden HPLC peaks, the volume of common tubing sizes, how to measure it and how to keep it small.

Successful passivation of an HPLC system

Passivating a stainless steel HPLC system: why metal ions spoil some analyses, the outline acid wash procedure, how often to repeat it, and PEEK alternatives.

Fittings for HPLC: types, threads and making a good connection

HPLC fittings explained: stainless steel and PEEK, nuts and ferrules, 10-32 and 1/4-28 threads, coned and flat-bottom ports, and how to make a leak-free joint.

Choosing the right tubing for your application

How to choose HPLC tubing: stainless steel, PEEK, PTFE and FEP compared, which inner diameter to use where, volume per length, pressure drop and cutting.

Gas chromatography and headspace

What is gas chromatography (GC)?

Gas chromatography explained: carrier gas, inlets, capillary columns and their phases, the oven programme, FID and other detectors, and what GC is used for.

Instructions for installing GC columns

How to install a GC capillary column: choosing ferrules, cutting the column cleanly, insertion depth, purging before heating, leak checking and conditioning.

GC liner: selecting an appropriate liner

How to choose a GC inlet liner: split and splitless designs, tapers, glass wool, deactivation, solvent expansion volume and backflash, and when to replace it.

Selection guide for GC syringes and needle tips

How to choose a GC syringe: bevelled, cone and side-hole needle tips, gauge and length, fixed or removable needles, gas-tight plungers, volume and syringe care.

Derivatisation for GC and reaction headspace: why and how

Why and how to derivatise for GC: silylation with BSTFA or MSTFA, acylation, methylation to FAMEs, choosing a reagent, working dry, and reaction headspace.

Basic principles of headspace analysis

The principles of static headspace GC: the two phases in the vial, equilibrium, partition coefficient and phase ratio, temperature, and vial and septum issues.

Headspace analysis in GC: definition, suitability and applications

Headspace GC explained simply: what it is, which samples and analytes it suits, uses such as residual solvents and blood alcohol, limits and calibration.

Headspace sample volume and the phase ratio

How sample volume affects headspace GC results: the phase ratio beta, worked figures for 20 mL vials, when more sample helps and when it does not.

Partition coefficient in headspace analysis

The partition coefficient K in headspace GC: definition, K values of common solvents in water, and how temperature, salt, pH and phase ratio change sensitivity.

Headspace analysis: the balanced pressure system

How balanced pressure headspace sampling works: equilibration, pressurisation, time-controlled transfer to the column, and its strengths and limits.

Headspace analysis: the pressurised loop system

How a valve-and-loop headspace sampler works: equilibration, pressurisation, loop fill, injection, temperature zones, and how to keep results repeatable.

Headspace analysis: the syringe injection system

How syringe-based headspace sampling works in three steps, its advantages on multi-purpose autosamplers, and how to avoid condensation and pressure losses.

Sample preparation and filtration

Vials, caps and consumables

Applications

Laboratory practice

Autoclave: how steam sterilisation works

How an autoclave sterilises: 121 °C and 134 °C cycles, why air must be removed, liquid and solid loads, what may be autoclaved, and how to verify a cycle.

pH measurement: pH meters, electrodes and buffer solutions

How to measure pH correctly: how the glass electrode works, calibrating with buffer solutions, slope and offset, temperature effects, storage and cleaning.

Pipettes: types, materials and areas of application

The types of laboratory pipette and what each is for: volumetric, graduated and serological, Pasteur and transfer pipettes, and air- and positive-displacement.

Pipetting techniques: forward, reverse and how to avoid errors

How to pipette accurately: forward and reverse technique, pre-wetting, immersion depth and angle, viscous and volatile liquids, common errors and checks.

Petri dishes: types, sizes and correct use

Petri dishes explained: plastic or glass, sizes from 35 to 150 mm, vented and non-vented lids, contact plates and divided dishes, pouring agar and incubation.

Nucleic acid decontamination: removing DNA, RNA and nucleases

How to prevent and remove DNA, RNA and nuclease contamination in a PCR laboratory: bleach, UV, what ethanol and autoclaving cannot do, and workflow design.

Hygiene monitoring in pharmacies and pharmaceutical settings

Hygiene monitoring in pharmacy aseptic units and cleanrooms: settle plates, contact plates, air samples, glove prints, limits by grade and trending.

Safety and order in the laboratory

The essentials of laboratory safety and order: labelling, no food or drink, protective equipment, chemical storage, housekeeping, waste and spills.

Sampling: how to take a representative sample

How to take a representative sample: sampling plans, grab and composite samples, the main sources of error, containers, preservation, blanks and documentation.

Conversion tables

A to Z

New products and price changes, once a month

No daily emails. Unsubscribe in one click.

  • New arrivals
  • Price changes
  • Brand offers

About once a month. Unsubscribe any time. See our privacy policy.

Lab guides and glossary | Lancetech Limited