Inch fractions to millimetres
| Fraction (inch) | Decimal (inch) | Millimetres (mm) |
|---|---|---|
| 1/32″ | 0.03125 | 0.79375 |
| 1/16″ | 0.0625 | 1.5875 |
| 3/32″ | 0.09375 | 2.38125 |
| 1/8″ | 0.125 | 3.175 |
| 5/32″ | 0.15625 | 3.96875 |
| 3/16″ | 0.1875 | 4.7625 |
| 7/32″ | 0.21875 | 5.55625 |
| 1/4″ | 0.25 | 6.35 |
| 9/32″ | 0.28125 | 7.14375 |
| 5/16″ | 0.3125 | 7.9375 |
| 11/32″ | 0.34375 | 8.73125 |
| 3/8″ | 0.375 | 9.525 |
| 13/32″ | 0.40625 | 10.31875 |
| 7/16″ | 0.4375 | 11.1125 |
| 15/32″ | 0.46875 | 11.90625 |
| 1/2″ | 0.5 | 12.7 |
| 17/32″ | 0.53125 | 13.49375 |
| 9/16″ | 0.5625 | 14.2875 |
| 19/32″ | 0.59375 | 15.08125 |
| 5/8″ | 0.625 | 15.875 |
| 21/32″ | 0.65625 | 16.66875 |
| 11/16″ | 0.6875 | 17.4625 |
| 23/32″ | 0.71875 | 18.25625 |
| 3/4″ | 0.75 | 19.05 |
| 25/32″ | 0.78125 | 19.84375 |
| 13/16″ | 0.8125 | 20.6375 |
| 27/32″ | 0.84375 | 21.43125 |
| 7/8″ | 0.875 | 22.225 |
| 29/32″ | 0.90625 | 23.01875 |
| 15/16″ | 0.9375 | 23.8125 |
| 31/32″ | 0.96875 | 24.60625 |
| 1″ | 1 | 25.4 |
| 2″ | 2 | 50.8 |
| 3″ | 3 | 76.2 |
| 4″ | 4 | 101.6 |
| 5″ | 5 | 127 |
| 6″ | 6 | 152.4 |
| 8″ | 8 | 203.2 |
| 10″ | 10 | 254 |
| 12″ | 12 | 304.8 |
| 24″ | 24 | 609.6 |
| 36″ | 36 | 914.4 |
Millimetres to inches: sizes used in the laboratory
| Millimetres (mm) | Inches | Where a lab meets it |
|---|---|---|
| 0.5 | 0.020″ | |
| 1 | 0.039″ | HPLC column inner diameter (micro) |
| 2.1 | 0.083″ | HPLC and UHPLC column inner diameter |
| 3 | 0.118″ | HPLC column inner diameter; small syringe filter |
| 4 | 0.157″ | HPLC column inner diameter; syringe filter |
| 4.6 | 0.181″ | HPLC column inner diameter (standard analytical) |
| 10 | 0.394″ | Semi-preparative column inner diameter |
| 13 | 0.512″ | Syringe filter and membrane diameter |
| 15 | 0.591″ | Syringe filter diameter |
| 20 | 0.787″ | |
| 25 | 0.984″ | Syringe filter and membrane diameter |
| 30 | 1.181″ | Short HPLC column length |
| 47 | 1.850″ | Membrane filter diameter for vacuum filtration |
| 50 | 1.969″ | HPLC column length; membrane diameter |
| 90 | 3.543″ | Membrane filter and Petri dish diameter |
| 100 | 3.937″ | HPLC column length |
| 110 | 4.331″ | Filter paper circle diameter |
| 125 | 4.921″ | HPLC column length; filter paper circle diameter |
| 150 | 5.906″ | HPLC column length; filter paper circle diameter |
| 250 | 9.843″ | HPLC column length |
| 300 | 11.811″ | Size-exclusion column length |
Tubing and capillary sizes quoted in inches
| Inches | Millimetres (mm) | Micrometres (µm) | Usually the |
|---|---|---|---|
| 0.005″ | 0.127 | 127 | inner diameter |
| 0.007″ | 0.1778 | 177.8 | inner diameter |
| 0.01″ | 0.254 | 254 | inner diameter |
| 0.02″ | 0.508 | 508 | inner diameter |
| 0.03″ | 0.762 | 762 | inner diameter |
| 0.04″ | 1.016 | 1016 | inner diameter |
| 0.03125″ | 0.7938 | 793.8 | outer diameter (1/32 inch) |
| 0.0625″ | 1.5875 | 1587.5 | outer diameter (1/16 inch), the usual HPLC capillary |
| 0.125″ | 3.175 | 3175 | outer diameter (1/8 inch) |
| 0.25″ | 6.35 | 6350 | outer diameter (1/4 inch) |
How to convert inches to mm
One inch is exactly 25.4 millimetres. The figure is a definition, agreed internationally in 1959, so the conversion has no rounding error of its own.
- Inches to millimetres: multiply by 25.4. Example: 0.25 inch x 25.4 = 6.35 mm.
- Inches to centimetres: multiply by 2.54. Example: 6 inches x 2.54 = 15.24 cm.
- Inches to micrometres (microns): multiply by 25,400. Example: 0.005 inch x 25,400 = 127 µm.
- Millimetres to inches: divide by 25.4. Example: 4.6 mm / 25.4 = 0.181 inch.
Converting a fraction of an inch
Turn the fraction into a decimal first, then multiply. For 3/16 inch: 3 / 16 = 0.1875, and 0.1875 x 25.4 = 4.7625 mm, which rounds to 4.76 mm.
Always convert the exact fraction and round only at the end. Rounding the decimal first (0.188 instead of 0.1875) gives 4.78 mm, a small error that is easy to avoid and that matters when a fitting has to seal.
Thou, mil and micrometres
Capillary and tubing bores are often quoted in thousandths of an inch. One thousandth of an inch (0.001 inch, called a thou or a mil) is 25.4 µm. So a 0.005 inch bore is 127 µm, 0.007 inch is about 178 µm and 0.010 inch is 254 µm.
Where a laboratory meets inches
Most laboratory dimensions are metric, but several everyday parts are still made to inch sizes:
- HPLC capillaries and tubing. The usual outer diameter is 1/16 inch (1.5875 mm). Larger solvent lines are 1/8 inch (3.175 mm). The bore is given in thousandths of an inch. See choosing HPLC tubing.
- Fitting threads. The common HPLC fitting thread is 10-32: a number 10 thread (0.190 inch, 4.83 mm across) with 32 threads per inch. Low-pressure flangeless fittings often use 1/4-28: a 1/4 inch (6.35 mm) thread with 28 threads per inch. See HPLC fittings.
- Packed GC columns and gas lines. Outer diameters of 1/8 inch and 1/4 inch are standard.
- Method documents. Methods written in the United States may give lengths in inches where a European method gives millimetres.
Dimensions that are metric almost everywhere include HPLC column length and inner diameter (for example 150 x 4.6 mm), capillary GC column bore (0.25, 0.32 and 0.53 mm), membrane and syringe filter diameters (13, 25 and 47 mm) and filter paper circles.
Worked example: filter diameters in inches
Syringe filters and membranes are sold by metric diameter. If a document quotes inches, the usual sizes convert as follows: 13 mm is 0.512 inch, 25 mm is 0.984 inch (often loosely called 1 inch) and 47 mm is 1.850 inch. A 25 mm filter and a "1 inch" filter are normally the same product; check the holder size if the fit matters. For choosing the diameter itself, see the syringe filter selection guide.
Rounding sensibly
Keep as many figures as the part needs. For a description, two decimal places of a millimetre are plenty. For a bore that sets a flow path, keep the micrometres: 0.005 inch is 127 µm, not "0.1 mm".