Celsius to Fahrenheit table for the laboratory
| Celsius (°C) | Fahrenheit (°F) | Kelvin (K) | Where a lab meets it |
|---|---|---|---|
| -196 | -320.8 | 77.15 | Liquid nitrogen (boils at about -196 °C) |
| -80 | -112 | 193.15 | Ultra-low freezer |
| -40 | -40 | 233.15 | The one point where both scales read the same |
| -20 | -4 | 253.15 | Laboratory freezer |
| 0 | 32 | 273.15 | Freezing point of water |
| 4 | 39.2 | 277.15 | Refrigerator (2 to 8 °C storage) |
| 8 | 46.4 | 281.15 | Upper limit of 2 to 8 °C storage |
| 15 | 59 | 288.15 | |
| 20 | 68 | 293.15 | Reference temperature for volumetric glassware |
| 25 | 77 | 298.15 | Reference temperature for pH buffers and conductivity |
| 30 | 86 | 303.15 | Common HPLC column oven setting |
| 35 | 95 | 308.15 | |
| 37 | 98.6 | 310.15 | Incubation at body temperature |
| 40 | 104 | 313.15 | Common HPLC column oven setting |
| 44 | 111.2 | 317.15 | Incubation for thermotolerant coliforms |
| 50 | 122 | 323.15 | |
| 60 | 140 | 333.15 | |
| 70 | 158 | 343.15 | |
| 80 | 176 | 353.15 | |
| 100 | 212 | 373.15 | Boiling point of water at standard pressure |
| 105 | 221 | 378.15 | Drying oven for moisture and total solids |
| 121 | 249.8 | 394.15 | Steam sterilisation in an autoclave |
| 134 | 273.2 | 407.15 | Steam sterilisation, short cycle |
| 150 | 302 | 423.15 | COD digestion in a heating block (148 to 150 °C, by method) |
| 180 | 356 | 453.15 | Dry heat sterilisation (typically 160 to 180 °C) |
| 200 | 392 | 473.15 | |
| 250 | 482 | 523.15 | Typical GC inlet temperature |
| 300 | 572 | 573.15 | |
| 350 | 662 | 623.15 |
How to convert Celsius to Fahrenheit
- Celsius to Fahrenheit: multiply by 9/5 (1.8) and add 32. Example: 25 °C x 1.8 + 32 = 77 °F.
- Fahrenheit to Celsius: subtract 32, then multiply by 5/9. Example: (98.6 °F - 32) x 5/9 = 37 °C.
- Celsius to Kelvin: add 273.15. Example: 25 °C = 298.15 K.
The two scales read the same at one point only: -40 °C is -40 °F.
Converting a temperature difference
A tolerance or a temperature step converts differently from a temperature: there is no 32 to add. A change of 1 °C is a change of 1.8 °F, and a change of 1 K is the same size as a change of 1 °C.
So a tolerance of plus or minus 2 °C is plus or minus 3.6 °F, and an oven ramp of 10 °C per minute is 18 °F per minute. Adding 32 to a difference is the most common conversion mistake.
Storage conditions in both scales
Product labels and pharmacopoeias describe storage by temperature range. The usual European wording, with the Fahrenheit equivalents:
| Condition | Celsius | Fahrenheit |
|---|---|---|
| Deep-freeze | below -15 °C | below 5 °F |
| Refrigerator | 2 to 8 °C | 35.6 to 46.4 °F |
| Cold or cool | 8 to 15 °C | 46.4 to 59 °F |
| Room temperature | 15 to 25 °C | 59 to 77 °F |
The United States Pharmacopeia defines controlled room temperature as 20 to 25 °C (68 to 77 °F). Where a certificate or a label states its own range, that range is the one to follow.
Why temperature matters at the bench
- Reference standards and reagents keep their stated purity only when stored as labelled.
- pH measurement depends on temperature: buffer values are quoted at 25 °C and the electrode slope changes with temperature. See pH measurement.
- HPLC retention times shift when the column temperature moves, which is why a column oven is used. See temperature and retention time.
- Sterilisation is defined by temperature and time together, for example 121 °C for at least 15 minutes in an autoclave.
A quick estimate, and its limit
For a rough check, double the Celsius figure and add 30: 20 °C gives about 70 °F (the true value is 68 °F). The shortcut is exact at 10 °C and drifts further from the truth the further you move from there, so use the formula or the calculator for anything you will write down.
General guidance from Lancetech Limited, reviewed 25 November 2026. Always follow your validated method, the instrument manual and the manufacturer's instructions for the product in your hands.