What a monoclonal antibody is
Antibodies are proteins made by the immune system that recognise and bind a specific target, the antigen. A monoclonal antibody (mAb) is a population of identical antibody molecules, all derived from a single cell line and all binding the same site on the same antigen.
Most therapeutic antibodies are of the immunoglobulin G (IgG) class. An IgG is a Y-shaped molecule of about 150 kDa, built from two identical heavy chains (about 50 kDa each) and two identical light chains (about 25 kDa each), held together by disulfide bonds. The tips of the arms bind the antigen. The stem interacts with the immune system and carries sugar chains (glycans) that influence the antibody's activity and lifetime in the body.
Hybridoma technology
Monoclonal antibodies became possible in 1975, when Georges Köhler and César Milstein fused antibody-producing cells from an immunised mouse with immortal myeloma cells. The resulting hybridoma cells both produce a single antibody and divide indefinitely. Selecting and growing one such cell gives an unlimited supply of one antibody. The work was recognised with a Nobel Prize in 1984.
Mouse antibodies provoke an immune response in patients, so the technology moved on to chimeric, humanised and fully human antibodies. Today most therapeutic antibodies are produced by recombinant DNA technology in mammalian cell cultures, most often Chinese hamster ovary cells.
Medical use
Monoclonal antibodies are among the most important classes of modern medicines. They are used in oncology, in autoimmune and inflammatory diseases such as rheumatoid arthritis and psoriasis, in transplant medicine, against some infections, and widely as reagents in diagnostic tests. Most have international names ending in "-mab"; names assigned since 2022 use the newer endings -tug, -bart, -mig and -ment. Related products include antibody-drug conjugates, in which a potent drug is attached to an antibody that delivers it to its target, and bispecific antibodies, which bind two targets.
Why they are hard to analyse
A therapeutic antibody is never a single molecular species. During production and storage it develops variants: aggregates and fragments, forms with different charge, oxidised and deamidated forms, and many patterns of glycosylation. Each can affect safety or efficacy, so each is monitored. No single method sees them all, which is why antibody analysis uses several complementary modes of HPLC.
Monoclonal antibodies and HPLC columns
| HPLC mode | What it measures | Typical column |
|---|---|---|
| Size exclusion (SEC) | Aggregates (dimers and larger) and fragments | Wide-pore silica or polymer with a hydrophilic bonded layer |
| Ion exchange (IEX) | Charge variants: acidic and basic forms | Weak or strong cation exchanger; salt or pH gradient |
| Hydrophobic interaction (HIC) | Oxidised variants; drug-to-antibody ratio of conjugates | Butyl or similar phase; decreasing salt gradient |
| Reversed phase (RP) | Intact mass, light and heavy chains after reduction, fragments | Wide-pore (about 300 Å) C4, C8 or diphenyl, at elevated temperature |
| Protein A affinity | Antibody concentration (titre) in cell culture | Immobilised Protein A |
| HILIC | Released, labelled glycans | Amide phase |
| Peptide mapping (RP) | Sequence confirmation and modifications, after enzyme digestion | C18, with mass spectrometric detection |
Points that apply across the modes:
- Wide pores. A 150 kDa protein needs pores of about 300 Å or more to reach the bonded surface (column selection).
- Low adsorption. Proteins stick to active silica and to metal. Columns and hardware described as bio-inert, or offering high protein recovery, reduce losses and tailing. Stainless steel systems may need attention: see passivation.
- Native or denaturing. Size exclusion, ion exchange and hydrophobic interaction use aqueous buffers that keep the protein folded. Reversed phase uses organic solvent, acid and heat, which unfold it.
- Salt. Many of these methods use high salt concentrations. Flush the system with water afterwards to prevent corrosion and blockage.
Sample handling
- Filter samples with low protein-binding membranes such as polyethersulfone, PVDF or regenerated cellulose (syringe filter selection).
- Use vials suited to proteins; some antibodies adsorb to glass or to plastic at low concentration, so check recovery (vial selection).
- Avoid repeated freezing and thawing, vigorous shaking and long exposure to room temperature, all of which create aggregates.
Purification
Production-scale purification follows a well-established sequence: capture on Protein A, low-pH virus inactivation, polishing by ion-exchange and other chromatography, virus filtration, and concentration and buffer exchange by ultrafiltration. Laboratory and process development work uses the same steps on a small scale, with prepacked columns, FPLC media and bioprocessing filters and membranes.
General guidance from Lancetech Limited, reviewed 25 November 2026. Always follow your validated method, the instrument manual and the manufacturer's instructions for the product in your hands.