Lancetech Limited
Laboratory practice

Petri dishes: types, sizes and correct use

Petri dishes explained: plastic or glass, sizes from 35 to 150 mm, vented and non-vented lids, contact plates and divided dishes, pouring agar and incubation.

  • 3 min read
  • 1 figure
  • Reviewed 25 November 2026
On this page 10 sections
  1. What a Petri dish is
  2. Plastic or glass
  3. Sizes
  4. Vented or non-vented lids
  5. Special designs
  6. Pouring agar plates
  7. Inoculating and incubating
  8. Counting colonies
  9. Disposal
  10. Avoiding common problems

What a Petri dish is

A Petri dish is a shallow, flat, round dish with a loosely fitting lid, named after the bacteriologist Julius Richard Petri, who introduced it in 1887. Filled with a nutrient gel, usually agar, it provides a surface on which microorganisms grow into visible colonies that can be counted, examined and isolated. Petri dishes are also used for cell culture, for germinating seeds, for drying and weighing small samples, and for general handling of specimens.

Plastic or glass

Polystyrene (disposable)Glass (reusable)
SuppliedSterile, ready to useNon-sterile; sterilise before each use
ClarityExcellentExcellent
Heat resistanceLow: cannot be autoclaved or heatedHigh: can be autoclaved and dry-heat sterilised
Chemical resistancePoor against organic solventsVery good
Typical useRoutine microbiology and cell cultureWork with solvents or heat; teaching; where waste must be minimised

Most microbiological work uses sterile disposable polystyrene dishes. Glass dishes of borosilicate glass are chosen where solvents, heat or repeated use are involved (chemical resistance of plastics).

Sizes

Nominal diameterTypical use
35 mmSmall cultures; cell culture; microscopy
55 to 60 mmSmall cultures; membrane filters of 47 or 50 mm; contact plates
90 to 100 mmThe standard dish for microbiology
140 to 150 mmLarger samples; susceptibility testing with many discs
Square, about 120 mmLarger area; grids for counting

A standard 90 mm dish takes roughly 15 to 25 mL of agar, depending on the depth the method requires.

Vented or non-vented lids

The lid rests on the base either directly or on small raised ridges (vents or cams).

  • Vented dishes hold the lid slightly above the rim, allowing air to exchange. This suits aerobic organisms and reduces condensation. Dishes are made with one or several vents.
  • Non-vented dishes let the lid sit on the rim. Less air is exchanged, so the agar dries more slowly: useful for long incubation.
Petri dishes in cross-section: a vented lid, a non-vented lid and a dish incubated upside downVentedRidges hold the lid up:air exchanges, less condensationNon-ventedLid rests on the rim:agar dries more slowlyIncubated upside downAgar on top: condensationcollects on the lid, not the agarAgarLidBase
Vented and non-vented lids, and why plates are incubated agar side up.

Special designs

  • Contact plates. Small dishes, about 55 mm, filled so that the agar surface stands slightly above the rim. Pressed against a flat surface, they sample it directly. Many have a counting grid on the base. They are the standard tool for monitoring surfaces (hygiene monitoring).
  • Divided dishes. Two, three or four compartments allow different media or samples in one dish.
  • Dishes with a grid help in counting colonies.
  • Cell culture dishes have a treated surface to which cells can attach. Untreated dishes are used for suspension cultures and for microbiology.

Pouring agar plates

  1. Prepare and sterilise the medium as its instructions state, normally in an autoclave.
  2. Let it cool to about 45 to 50 °C in a water bath. Hotter agar causes heavy condensation and can damage heat-sensitive additives, which are added at this stage; cooler agar begins to set.
  3. Working aseptically, lift the lid just enough to pour, and pour steadily to avoid bubbles.
  4. Leave the dishes on a level surface until set.
  5. Dry the surface if the method requires it, and store the plates inverted in closed bags at 2 to 8 °C, away from light. Label with the medium and the date, and use them within the period validated for that medium.

Inoculating and incubating

  • Label the base, not the lid, since lids can be swapped by mistake.
  • Work aseptically, opening dishes for as short a time as possible.
  • Incubate dishes inverted, agar side up, so that condensation does not drip onto the surface and spread the colonies.
  • Do not stack too many dishes: those in the middle of a tall stack warm up more slowly.
  • Use the temperature, atmosphere and time that the method specifies.

Counting colonies

Results are expressed as colony-forming units (cfu). Counts are reliable only within a range: with too few colonies the statistical uncertainty is large, and with too many they merge and compete. Standard methods state the countable range for each dish size; dilute the sample so that at least one dilution falls within it.

Disposal

Used plates carry live cultures. Collect them in suitable bags or containers and decontaminate them, normally by autoclaving, before disposal, in line with your laboratory's biosafety rules.

Avoiding common problems

ProblemLikely cause
Water on the lid and agar surfaceAgar poured too hot; dishes cooled too quickly; plates stored or incubated lid up
Contaminated platesPoor aseptic technique; draughts; medium or dishes not sterile
Agar drying or crackingIncubation too long for the fill depth; vented dishes in a dry incubator
Spreading or merged coloniesWet agar surface; too many organisms plated
Uneven agar depthDishes not level while setting

General guidance from Lancetech Limited, reviewed 25 November 2026. Always follow your validated method, the instrument manual and the manufacturer's instructions for the product in your hands.

New products and price changes, once a month

No daily emails. Unsubscribe in one click.

  • New arrivals
  • Price changes
  • Brand offers

About once a month. Unsubscribe any time. See our privacy policy.

Petri dishes: sizes, vented or not, glass or plastic, and how to use | Lancetech Limited