Photometric tube tests
Photometric tube tests are pre-dosed reagent tubes that give a quantitative reading in a photometer. Wastewater plants, drinking water laboratories and industrial effluent teams use them for routine water analysis of nutrients, metals and sum parameters.
The 203 Macherey-Nagel listings are NANOCOLOR tests and reagents. Examples include the aluminium standard test for 0.01 to 1.00 mg/L Al3+ sufficient for 250 determinations, the ammonium standard test for 0.01 to 2.0 mg/L NH4-N for 100 determinations, an AOX expansion kit for the sensitive AOX range and a chloride detection kit for AOX determinations in samples with high chloride content.
Choose a tube test by parameter and measuring range, then check the number of determinations per pack against your sampling schedule. Pair these tests with NANOCOLOR photometers and accessories from the neighbouring section. Ask Lancetech Limited for a quotation on the parameters you test most often.
Filters
Shelf life (from production)
1 Year(s)1052 Year(s)381.5 Year(s)283 Year(s)1912 Month(s)23 Month(s)26 Month(s)22.5 Year(s)18 Month(s)1
NANOCOLOR Aluminium standard test measuring range: 0.01-1.00 mg/L Al3+ sufficient for 250 determinations

NANOCOLOR Ammonium standard test measuring range: 0.01-2.0 mg/L NH4-N 0.01-2.5 mg/L NH4+ sufficient for 100 determinations

NANOCOLOR AOX expansion kit for sensitive AOX range pack of 2 x 4 g, for 20 determinations

NANOCOLOR Chloride detection kit for AOX determinations with high chloride contents pack of 10 mL

NANOCOLOR Crack set __UN 3316 Chemical kit 9 II 0.100 L ADR/GGVSEB M11 (E) ADR 3.3.1/251: LQ PAX 960 10 Kg CAO 960 10 Kg

NANOCOLOR Lead (without CCl4) Standard test (additionally carbon tetrachloride is necessary) consists of 2 boxes

NANOCOLOR Manganese standard test measuring range: 0.005 – 3.00 mg/L Mn sufficient for 250 determinations

NANOCOLOR Iron LR Standard test 0.005 - 5.00 mg/L Fe

NANOCOLOR Cadmium (without CCl4) Standard test (additionally carbon tetrachloride is necessary)

NANOCOLOR Fluoride standard test measuring range: 0.05-2.00 mg/L F- sufficient for 500 determinations

NANOCOLOR Chlorine standard test measuring range: 0.02-10.0 mg/L Cl2 sufficient for 250 determinations

NANOCOLOR Chlorine dioxide standard test measuring range: 0.04-4.00 mg/L ClO2 sufficient for 50 determinations

NANOCOLOR Bitter units For evaluation in 10 mm cuvettes Test with Barcode For evaluation in 10 mm quartz cuvettes pack of 20 tests

NANOCOLOR Chloride standard test measuring range: 0.2-125 mg/L Cl- sufficient for 250 determinations

NANOCOLOR Chromate standard test measuring range: 0.01-3.0 mg/L Cr(VI) 0.01-6.0 mg/L CrO42- sufficient for 250 determinations

NANOCOLOR Cyanide standard test measuring range: 0.001-0.50 mg/L CN- sufficient for 250 determinations

NANOCOLOR Detergents anionic Standard test

NANOCOLOR Detergents cationic Standard test

NANOCOLOR Iron standard test measuring range: 0.01-15.0 mg/L Fe sufficient for 250 determinations

NANOCOLOR Hydrazine standard test measuring range: 0.002-1.50 mg/L N2H4 sufficient for 250 determinations

NANOCOLOR Silica standard test measuring range: 0.01-5.00 mg/L Si 0.002-0.100 mg/L Si 0.02-10.0 mg/L SiO2 0.005-0.200 mg/L SiO2 sufficient for 250 determinations

NANOCOLOR Sludge Reagent set IATA (Aircraft, Cargo only): list single components

NANOCOLOR Cobalt standard test measuring range: 0.002-0.70 mg/L Co2+ sufficient for 250 determinations