GC Columns
GC columns are the capillary columns at the heart of every gas chromatography separation, chosen by stationary phase, internal diameter, film thickness and length. Environmental, food, petrochemical and pharmaceutical laboratories depend on GC columns for volatile and semi-volatile analysis.
The 609 listings are all Macherey-Nagel. Among them are PERMABOND CW 20 M capillary columns in 0.25 mm internal diameter with a 0.25 µm film, in 10 m, 25 m, 30 m and 50 m lengths, with many further phases and dimensions in the range.
Select the phase for your analyte polarity, a narrower bore and thinner film for resolution and speed, and a longer column when closely eluting peaks need separating. Lancetech Limited supplies Macherey-Nagel GC columns to UK laboratories and will quote on method-specific requirements.
Filters (2 active)
Column Description
OPTIMA-516OPTIMA-113PERMABOND5Optima Delta 32Optima 2251Optima FFAP1Optima Delta 61OPTIMA-171Max. Operating Temperature
up to 340/360°C28up to 220/240°C5up to 380/400°C4up to 260/280°C1up to 250/260°C1up to 320/340°C1
GC Capillary column PERMABOND CW 20 M ID: 0.10 mm, film thickness: 0.10 µm Length: 10 m

GC Capillary column PERMABOND FFAP ID: 0.1 mm, film thickness: 0.1 µm length: 10 m

GC Capillary column PERMABOND FFAP ID: 0.1 mm, film thickness: 0.1 µm length: 20 m

GC Capillary column PERMABOND FFAP ID: 0.32 mm, film thickness: 0.1 µm length: 25 m

GC Capillary column PERMABOND FFAP ID: 0.32 mm, film thickness: 0.1 µm length: 50 m

GC Capillary column OPTIMA 1 ID: 0.10 mm, film thickness: 0.10 µm length: 10 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.10 mm, film thickness: 0.10 µm length: 20 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.25 mm, film thickness: 0.10 µm length: 10 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.25 mm, film thickness: 0.10 µm length: 15 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.25 mm, film thickness: 0.10 µm length: 25 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.25 mm, film thickness: 0.10 µm length: 30 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.25 mm, film thickness: 0.10 µm length: 60 m pack of 1

GC Capillary column OPTIMA 225 ID: 0.10 mm, film thickness: 0.10 µm length: 10 m pack of 1

GC Capillary column OPTIMA 5 HT ID: 0.25 mm, film thickness: 0.10 µm length: 15 m pack of 1

GC Capillary column OPTIMA 5 HT ID: 0.25 mm, film thickness: 0.10 µm length: 30 m pack of 1

GC Capillary column OPTIMA 5 HT ID: 0.32 mm, film thickness: 0.10 µm length: 15 m pack of 1

GC Capillary column OPTIMA 5 HT ID: 0.32 mm, film thickness: 0.10 µm length: 30 m pack of 1

GC Capillary column OPTIMA FFAP ID: 0.10 mm, film thickness: 0.10 µm length: 10 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.32 mm, film thickness: 0.10 µm length: 10 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.32 mm, film thickness: 0.10 µm length: 25 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.32 mm, film thickness: 0.10 µm length: 30 m pack of 1

GC Capillary column OPTIMA 1 ID: 0.32 mm, film thickness: 0.10 µm length: 50 m pack of 1