Certified Reference Standards
Certified Reference Standards are the materials analytical laboratories use to calibrate instruments, validate methods and check results. This section gathers the reference standards used by pharmaceutical QC, environmental testing, food and water laboratories across the UK.
The range is led by European Pharmacopoeia (EP) reference standards and TOKU-E primary reference standards such as Actinomycin D in 5 mg, 10 mg and 25 mg packs. Alongside these sit Apera Instruments turbidity standard sets (20, 100, 400 and 800 NTU) for TN400 and TN480 meters, with further sections for pH buffers, conductivity and redox standards, AAS and ICP standards, titration and volumetric solutions, and TOC and TIC standards.
When choosing a reference standard, start from the method: a pharmacopoeia monograph calls for the matching EP standard, while instrument calibration needs a standard matched to the parameter, concentration range and sample matrix. If the exact material is not listed, Lancetech Limited can quote it on request.
Filters (2 active)

6 components: 2 g/l each of n-Pentane ; n-Hexane ; n-Heptane ; n-Octane ; n-Nonane ; n-Decane in Methanol – CRM, 1 ml

25 components: 2000 µg/ml each of Benzene ; Bromodichloromethane ; Tribromomethane ; Tetrachloromethane… – CRM, 1 ml

2 components: 100 µg/ml each of Metribuzin ; Etrimfos in Acetone – CRM, 1 ml

2 components: 50000 mg/l each of Mineral Oil ; Diesel Oil in n-Hexane – CRM, 1 ml

8 components: 100 mg/l each of cis-Bifenthrin ; Cyfluthrin ; lambda-Cyhalothrin ; Cypermethrin ;… – CRM, 1 ml

7 components: 100 mg/l each of Chloroform ; Bromodichloromethane ; 1,2-Dichloroethane ;… – CRM, 1 ml

7 components: 100 mg/l each of BDE 153 ; BDE 154 ; BDE 183 ; BDE 47 ; BDE 99 ; BDE 28 ; BDE 100 in Iso-octane – CRM, 1 ml

9 components: 100 mg/l each of MCPA ; Mecoprop ; 2,4,5-T ; Dichlorprop ; 2,4-DB ; 2,4-D ; Fenoprop ;… – CRM, 1 ml

22 components: 100 mg/l each of Benzo(b)fluoranthene ; Chrysene ; Dibenzo(a,h)anthracene ; Fluoranthene… – CRM, 1 ml

UCMR 6 – EPA Method 524.3 Enhanced Sensitivity Calibration Standard 8 components – CRM, 1 ml

EU Drinking Water Directive 2020/2184 – HAA5 Calibration Standard 5 components – CRM, 1 ml

EU Regulation 2023/915 – PAH4 Calibration Standard 4 components – CRM, 1 ml

EU Water Watch List 2025/439 – Sunscreen Agents Standard 4 components – CRM, 1 ml

EU Water Watch List 2025/439 – 6PPD and 6PPD-Quinone Standard 2 components – CRM, 1 ml

EU Water Watch List 2025/439 – Azole Compounds Calibration Standard 10 components – CRM, 1 ml

EU Water Watch List 2025/439 – Oxytetracycline and Tetracycline Calibration Standard 2 components – CRM, 1 ml

EU Water Watch List 2025/439 – Abamectin (Avermectin B1a + B1b) Calibration Standard 2 components – CRM, 1 ml

UCMR 6 – EPA Method 525.3 Semivolatile Organic Compounds Standard 13 components – CRM, 1 ml

UCMR 6 - EPA 563 Calibration Mix 7 components – CRM, 1 ml

Methyl mercaptan 100 µg/ml in Methanol – CRM, 1 ml

Toluene D8 2000 µg/ml in Methanol – CRM, 1 ml

Fluazifop-P-butyl 100 mg/l in Acetonitrile – CRM, 1 ml

Mancozeb 100 µg/ml in Acetonitrile – CRM, 1 ml